HOME >> 威尼斯人app最新 SERVICE >> 威尼斯人app最新 Valve >> SSV-A400Safety Shut-off Valve
Features※Low pressure drop due to in-line flow design ※Replace internal parts without dismantling the valve from the line ※Equipped with pressure compensating valve ※Emergency manual release local position indicator standard ※Electric release and electric remote indication of valve position available ※High response accuracy and short response time ※Max. flow rate should not exceed 80 m/sec, noise <80dB ※TUV SIL3 certificate according to SIL-norm IEC 61508 IEC 61511 Technical Data
Operating principleSafety shut-off valve is controlled by pilot . Overpressure or underpressure release feature is when monitored downstream operating pressure exceeds set-point range, the pressure signal fed back to the pilot (pilot valve), the pilot piston moving up or moving down, so that the trolley trip, hammer down the impact of the firing pin and firing pin moves down makes disengage the hook and flap, flap valve is closed down, thereby cutting off gas to the downstream pipeline, protect downstream equipment and pipeline safety.
Valve Design
Command Design
Dimensions SSV - A400 DN25 – DN150
SSV - A400 DN250 - DN400
The sampling point pressure piping connecting dimensions
Pressure sampling point mounting positionAs shown in Figure 1 and 2, the safety shut-off valve (SSV) pressure sampling point is 5-8xDN from the working valve (PCV or PV) .
Product order type selectionShut-off valve selection ![]() Pilot selection
Other special feature
|
专业顾问
威尼斯人app最新 Tel:+86 22 22193891/92/93